Bradley 16, Arthur Bradley Ph.D., author of the Handbook to Practical Disaster Preparedness for the Family, 3rd Edition, Prepper’s Instruction Manual: 50 Steps to Prepare for any Disaster, Disaster Preparedness for EMP Attacks and Solar Storms (Expanded Edition), and the Frontier Justice (The Survivalist Book 1)," https://thesurvivalmom.com/long-term-blackout-nuclear-meltdown/)
Emergency systems Nuclear plants obviously require electricity to operate their cooling pumps, not to mention their control systems. That power is normally tapped off of the electricity that the reactor generates. If the plant is offline, the power is provided by the electrical grid. But what happens when the grid itself goes down? The short answer is that large on-site diesel generators automatically activate to provide electricity. And if those should fail, portable diesel generators, which are also on-site, can be connected. Recent standardization has also ensured that generators can be swapped between plants without the need to retrofit connectors. There are also a couple of additional emergency systems that can be used specifically to cool the reactor. These include the turbine-driven-auxiliary-feedwater pump, which uses steam generated by the reactor to power a cooling turbine. The pump requires an operator, but it runs completely without electricity. This system, however, is meant only for emergency cooling of the reactor during those critical first few days when the fuel rod assemblies are being brought down in temperature, not for long-term cooling. And finally, in the worst case, most plants have a method of bringing in river or ocean water to flood the reactor. This typically damages the cooling system, but again, it helps to cool and cover the reactor core should all else fail. Unlike in other countries, permission from the federal government is not required to flood the reactor. Worst-case power-loss scenario With backup systems to the backup systems, it would seem that there’s nothing to worry about, right? Under all but the direst of circumstances, I think that assessment is correct. However, one could imagine a scenario in which the grid was lost and the diesel generators ran out of fuel. Speaking of fuel, how much is actually stored onsite? It depends on the plant, but at the Watts Bar Nuclear Plant, for example, there is enough fuel to run the emergency diesel generators for at least 42 days. I say at least because it would depend on exactly what was being powered. Once the reactor was cooled down, a much smaller system, known as the Residual Heat Removal System, would be all that was required to keep the fuel assemblies cool, both in the reactor and the spent fuel rods pool. The generators and onsite fuel supply could power that smaller cooling system for significantly longer than if they were powering the larger reactor cooling system. Even if we assumed a worst case of 42 days, it’s hard to imagine a scenario in which that would not be enough time to bring in additional fuel either by land, water, or air. Nonetheless, let’s push the question a little further. What would happen in the unlikely event that the diesel fuel was exhausted? Even with the reactor having been successfully cooled, the biggest risk would continue to be overheating of the fuel rod assemblies, both in the reactor and the spent fuel rods pool. Without circulation, the heat from the fuel rod assemblies could boil the surrounding water, resulting in steam. In turn, the water levels would drop, ultimately exposing the fuel rods to air. Once exposed to air, their temperatures would rise but not to the levels that would melt the zirconium cladding. Thankfully, that means that meltdown would not occur. The steam might well carry radioactive contaminants into the air, but there would be no release of hydrogen and, thus, no subsequent explosions. The situation would certainly be dangerous to surrounding communities, but it wouldn’t be the nuclear Armageddon that many people worry about.